Skip navigation.
Home

UTP – Category 3 – Indoors
imagen Perfil: 
Foto: 
Sellos Imagen: 
Sellos Imagen: 
Producto Ecologico: 

Norms: EIA/TIA - 568-B ISO/IEC 11801 Class C
Max. temperature of Service: 80 °C

Uses

In telephone installations (voice) and data transmission in networks.

Characteristics:

Solid copper Conductor gauge 0,51 mm (24 AWG) PE (Polythene) insulation, paired and wired upon protocol, PVC external Jacket, no flame-spread and auto-extinguishable. APT FOR VOICE AND DATA INSTALLATIONS from 10Mbps to 16Mbps.

Upon request:

LAN Line Cat. 3e for exterior and with self-supported load bearing.
Imagen: 
Imagen: 
Imagen: 
Imagen: 
Imagen: 
Imagen: 
Imagen: 

[+] Technical Information

AWG gaugeMax. Resistance At 20 °C (OHM/Km)Impedance (OHM)Mutual Electric Capacitance (PF/m)Frequency (Mhz)Attenuation(dB/100m)
24 (0,51 mm)90100 ± 15%6512.6
24 (0,51 mm)90100 ± 15%6545.61
24 (0,51 mm)90100 ± 15%6588.5
24 (0,51 mm)90100 ± 15%65109.7
24 (0,51 mm)90100 ± 15%651613.1

Code UTPN° of PairsInsulation widthJacket width (mm)Final diameter (mm)Weight (Kg/km)
R3 0022420,200.502.8017.2
R3 0032430,200.503.8021.2
R3 0042440,200.604.1027.6
R3 0062460,200.605.8039.2
R3 01224120,200.758.1079.5
R3 02524250,200.9010.40152.8
R3 05024500,201.0016.50310.7
R3 102241000,201.1022.80638.6